8. FIRST PLACING INTO OPERATION

BEFORE SWITCHING ON

Before switching on, half fill the cups with T lubricant or with the appropriate solvent (only for standard
fluid sections, not for Flowmax® fluid sections).
Nota : the cup nut must be slightly tightened with the wrench provided. Too much tightening may
damage the cup seals.
Tightening of the wetting cup :
- Fill the cup with T lubricant,
- Start the pump, then tighten the cup after 10 minutes, then 1 hour, then 1 day of operating,
- If you notice any leakage, the cup must be tightened.
Nota : Stop the machine and depressurize the air and fluid networks to tighten the cup.

FLUSHING OF THE PUMPS AND OF THE MACHINE IN SOLVENT

During that first placing into operation, it is compulsory to have all the pumps into
solvent as well as the machine to ensure the good quality of the fluid get by the PU
3000.
The fluid pressure must not exceed 1 bar / 14.5 psi on the gauges.
Carry out the connections indicated at § 5 (INSTALLATION),
Immerse the suction rod of the BASE pump in the solvent container,
Close the gun air supply valve,
On the page of the display main menu, enter 'NORMAL OPERATING' (F5 then
select the A pump (
Trigger the gun to start the A pump with solvent and increase the fluid pressure to at least 1
bar / 14.5 psi (reading on the gauge) or go through the drain valves,
Release the gun trigger when there are no more air bubbles in the solvent at the gun nozzle,
Immerse the suction rod of the CATALYST pump in a solvent container,
On the page of the display main menu, enter 'NORMAL OPERATING' (F5 then
select the B pump (
Trigger the gun to start the B pump with solvent and increase the fluid pressure to at least 1
bar / 14.5 psi (reading on the gauge) or go through the drain valve,
Release the gun trigger when there are no more air bubbles in the solvent at the gun nozzle,
Turn the air valve that supplies air to the flushing pump,
On the page of the display main menu, enter 'FLUSHING MODE' (F2 then
Trigger the gun to prime the SA pump with solvent and increase the fluid pressure to at least
1 bar / 14.5 psi (reading on the gauge),
Release the gun trigger when there are no more air bubbles in the solvent at the gun nozzle,
Do not modify the factory parameters for the moment.
L
K
Go out from the 'NORMAL OPERATING' mode passing to ESC.
Close the air supply valve of the flushing pump.
SAMES KREMLIN
OK
,
or
and
OK
,
or
and
Caution : Do not supply gun with atomising air to prevent any
atomisation and point the solvent fan into a container.
We advise you to wear protective glasses and gloves.
Page 19
)
,
)
,
OK
), then
OK
), then
OK
),