Validation Of The Initialization Mode - SAMES KREMLIN PU3000 2L 53/1 Translation From The Original Manual

Electronic mixing machine
Table of Contents

Advertisement

VALIDATION OF THE INITIALIZATION MODE

That mode enables the machine to define the high and low settings of the movement sensor on each
pump.
After validating the
stroke on the BASE pump piston : open the gun or the BASE drain valve to make the piston go down.
Once the BASE pump piston is in low position, close immediately the valve or the gun avoid the
decompression of the circuit, then input
Then, the piston displays
the gun or the BASE drain valve to make the piston go up.
OK
Input
.
The machine displays
the CATA drain valve to make the piston go down.
Once the CATA pump piston is in low point, close immediately the valve or the gun avoid the
decompression of the circuit, then input
Then, the piston displays
the gun or the CATA drain valve to make the piston go up. When the piston is up, close immediately
the circuit to avoid the decompression.
OK
Input
.
After that last validation, the machine comes back to the parameter
Caution : that parameter must be modified only when changing the sensor
(disassembly or re-cabling) or when updating the software or or of the
electronic card or when changing a barrier Zener (CA and CB only). If the
procedure is launched, it must be carried out in entirety, if not : the machine
will not work correctly any more.
SAMES KREMLIN

parameter, the machine displays
.
OK
A2
, it goes up and is waiting for the high setting of the BASE pump. Open
b1
, and controls the down stroke of the CATA pump piston : open the gun or
OK
.
b2
, it goes up and is waiting for the high setting of the CATA pump : open
Page 25
A1
, and controls the down

menu.
Manual : 573.199.112

Advertisement

Table of Contents
loading

Table of Contents