DIAGNOSTICS

ELECTRIC
The machine does not switch on
MATERIAL
No fluid flows when passing into production or
flushing mode.
The machine displays the correct mixing but the
consumption of catalyst is too important.
The machine displays the correct mixing but the
consumption of catalyst is not enough.
When the main menu page is displayed, fluid flows
out when the gun is open.
SAMES KREMLIN
FAULTS
FAULTS
Page 38
CHECKINGS
Check that the isolating switch is on 'I'.
Check that the mains supply is connected.
No : connect it.
Check that the fuse on the electric card inside the
box is in working order.
No : change the fuse.
Check the electric wiring of the supply cable (bad
contact or other)
CHECKINGS
Check if the valves are open :
No : - Check air supply (minimum 4 bar / 58 psi),
- Check the connection of the 25 pts cable,
- Check the correct operating of the
electrovalves.
Yes : - Check the fluid pressure,
- Check the static mixer.
Check the grounds of the machine (230V intake
and ground cable of the fluid module)
Check the grounds of the machine.
Check the valves
Checking of the valve : look at what is flowing
-if it is solvent, change the valve (VP1)
-if it is base, change the valve (VP2A)
-if it is catalyst, change the valve (VP2B)
Manual : 573.199.112