15 Do A Test Of The Emergency Power Unit; 16 Do A Test Of The Manual Platform-Leveling; 17 Do A Test Of The Steer Function - Skyjack SJ63 AJ+ Operation Manual

Articulating booms
Hide thumbs Also See for SJ63 AJ+:
Table of Contents

Advertisement

Section 4 – Inspections Before Operation
4.3-15 Do a test of the emergency power
unit
CAUTION
Do not operate more than one function at a time
when you use the emergency power. If you do so,
it will overload the 12-Volt emergency pump motor.
NOTE
To conserve the battery power, do a test of each
function through part of a cycle.
1. On the platform control console, push the
emergency-stop button to turn the engine off.
2. Pull the emergency-stop button.
3. Select the on position from the engine start/on/
off switch.
4. Press and hold the footswitch.
5. Select the emergency-power unit switch
and operate each function control handle or
switch.
Result: All the boom functions operate. The
drive and steer functions do not operate.
213211AAA
58
12
TM
1
+
+
2
4.3-16 Do a test of the manual platform-
leveling
1. Start the engine.
2. Press and hold the footswitch.
3. On the platform-leveling override switch
select the up position to tilt the platform up or
the down position to tilt the platform down.
Result: The platform tilts up or down.

4.3-17 Do a test of the steer function

1. Pull the emergency-stop button.
2. Select the start position from the engine start/
on/off switch to start the engine.
3. Press and hold the footswitch.
4. Press the steering rocker switch
the drive/steer controller to steer left and right.
Result: The steer wheels turn left and right.
5. Put the wheels in the parallel position before you
11
continue with the next test.
11
13
13
Function tests
12
on top of
SJ63 AJ+

Advertisement

Table of Contents
loading