Specifications - FLIR Extech Instruments 380941 User Manual

Ac/dc mini clamp meter
Table of Contents

Advertisement

Specifications

General Specifications
Display
Functions
Polarity
Current sensor
Overload indication
DCA zero adjust
Display rate
Battery
Operating
temperature
Operating humidity
Power
consumption
Weight
Dimensions
Jaw opening
Standards
Range Specifications
Function
DC Current
AC Current
DC Voltage
AC Voltage
Resistance
Frequency
3-3/4 (4000 count) Digit LCD with 40 segment bargraph
ACA, DCA, ACV, DCV, Resistance, Frequency, Continuity
"-" indicates negative polarity
Hall effect sensor type
Left blinking digit
One touch zero key
2 readings/second (20 readings/second for bargraph)
Two 1.5V AA batteries
o
o
4
F to 122
F (-10
< 85% RH
Approximately 10mA DC
8 oz. (225g) including battery
7 x 1.75 x 1.25" (178 x 45 x 32mm) (HWD)
0.9" (23mm)
IEC 1010 Category III 300V, Category II 600V
Range
Resolution.
40A
10mA
0 to 150A
100mA
150 to 200A
100mA
40A
10mA
0 to 150A
100mA
150 to 200A
100mA
400V
0.1V
400V
0.1V
0.1
40 to 400Ω
100 to 10k
0.01Hz
o
o
C to 50
C)
Accuracy
±(1.0% +2dgts)
±(1.0% +2dgts)
±(2.2% +2dgts)
50/60Hz
±(1.0% +3dgts)
±(1.0% +3dgts)
±(2.2% +3dgts)
±(1.0% +2dgts)
50/60Hz
±(1.5% +2dgts)
±(1.0% +2dgts)
±0.5% ±2dgts
5
Overload
protect
400A DC
400A DC
400A DC
40 to 400Hz
±(1.5% +4dgts)
400A AC
±(1.5% +4dgts)
400A AC
±(2.5% ±4dgts)
400A AC
1000VDC
40 to 400Hz
±(2.0% +4dgts)
800V AC
600V AC
Beeper <38Ω
Sensitivity;
600V AC
2V, 0.1A AC
380941-EN-V3.2-3/12