Specifications - FLIR Extech Instruments 410 User Manual

Table of Contents

Advertisement

Specifications

Function
Range
DC Voltage
200mV
(V DC)
2V
200V
1000V
AC Voltage
(V AC)
2V
200V
750V
DC Current
200μA
(A DC)
200mA
20A
AC Current
(A AC)
200mA
20A
Resistance
200Ω
2000Ω
20kΩ
200kΩ
20MΩ
Temperature
NOTE: Accuracy specifications consist of two elements:
• (% reading) – This is the accuracy of the measurement circuit.
• (+ digits) – This is the accuracy of the analog to digital converter.
NOTE: Accuracy is stated at 18
Resolution
0.1mV
0.001V
0.1V
1V
0.001V
0.1V
1V
0.1μA
0.1mA
0.01A
0.1mA
0.01A
0.1Ω
0.01kΩ
0.1kΩ
0.01MΩ
-20 to
1ºF
750ºC
-4 to
1ºC
1382ºF
o
o
C to 28
C (65
Accuracy
±(0.3% reading + 2 digits)
±(0.5% reading + 2 digits)
±(0.8% reading + 2 digits)
50 to 400Hz
±(1.0% reading +6
digits
±(1.5% reading +6
digits
±(2.0% reading +6
digits
±(1.5% reading + 3 digits)
±(2.5% reading + 3 digits)
50 to 400Hz
±(1.8% reading +8
digits
±(3.0% reading +8
digits)
±(0.8% reading +4 digits)
±(0.8% reading +2 digits)
±(1.0% reading +2 digits)
±(2.0% reading +5 digits)
±(3.0% reading +3 digits)
(meter only, probe accuracy not included)
o
o
F to 83
F) and less than 75% RH.
11
EX410-EU_ENG
400Hz to 1kHz
±(2.0% reading + 8
digits
±(2.5% reading +8
digits
±(3.0% reading +8
digits
400Hz to 1kHz
±(2.5% reading +10
digits)
±(3.5% reading +10
digits)
V5.1
10/07

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ex410a