Specifications - FLIR Extech 470 User Manual

True rms multimeter plus ir thermometer
Table of Contents

Advertisement

Specifications

Function
Range
DC Voltage
400mV
4V
40V
400V
1000V
AC Voltage
400mV
4V
40V
400V
750V
DC Current
400A
4000A
40mA
400mA
4A
20A
AC Current
400A
4000A
40mA
400mA
4A
20A
Resistance
400
4k
40k
400k
4M
40M
Capacitance
40nF
400nF
4F
40F
100F
Temp
-20 to 750C
(type-K)
-4 to 1382F
Temp
-50 to 270C
(IR)
-58 to 518F
NOTE: Accuracy is stated at 18
Resolution
0.1mV
(0.3% reading + 2 digits)
0.001V
(0.5% reading + 2 digits)
0.01V
0.1V
1V
(0.8% reading + 3 digits)
(1.5% reading + 15
0.1mV
digits)
0.001V
(1.5% reading + 6
0.01V
digits)
0.1V
1V
(1.8% reading + 6
digits)
0.1A
1A
(1.5% reading + 3 digits)
0.01mA
0.1mA
0.001A
(2.5% reading + 5 digits)
0.01A
0.1A
1A
(1.8% reading + 8
digits)
0.01mA
0.1mA
(3.0% reading + 8
0.001A
digits)
0.01A
(0.8% reading + 4 digits)
0.1
(0.8% reading + 2 digits)
0.001k
0.01k
(1.0% reading + 2 digits)
0.1k
0.001M
(3.0% reading + 5 digits)
0.01M
(5.0% reading + 7 digits)
0.01nF
0.1nF
(3.0% reading + 5 digits)
0.001F
(3.5% reading + 5 digits)
0.01F
(5.0% reading + 5 digits)
0.1F
(3.0% reading + 3 digits)
1C
(probe accuracy not included)
1F
1C
2.0% reading or 2C,  4 F
1F
o
o
o
C to 28
C (65
F to 83
13
Accuracy
50 to 400Hz
50 to 400Hz
o
F) and less than 75% RH.
400Hz to 1kHz
(2.5% reading + 15digits)
(2.5% reading + 8 digits)
(3% reading + 8 digits)
400Hz to 1KHz
(3.0% reading + 7 digits)
(3.5% reading + 10
digits)
EX470-EU-EN-V5.4-5/12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extech ex470-nist

Table of Contents