Page 1
5004 FRL UK - ASSEMBLY AND INSTRUCTIONS MANUAL SCAN 5004 FRL ASSEMBLY AND INSTRUCTION MANUAL SCAN 5004 FRL...
Page 2
5004 FRL CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-bur- ning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
CONTENTS ¬ ¬ TECHNICAL DATA Installation Dimension sketch Scan 5004 FRL Safety Type plate Technical data and dimensions Product registrationumber ¬ ¬ ASSEMBLY Additional accessories Before building the insert Disposal of packaging Fresh air intake Load-bearing foundation Closed combustion system...
Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
Surface treatment Senotherm Dust @ 13% O mg/Nm Max. log length 40 cm No x @ 13% O mg/Nm Weight Scan 5004 FRL 210 kg Efficiency Weight Scan 5004 FRL Energy efficiency index 218 kg w/heat shield Energy efficiency class Flue conn.
DIMENSION SKETCH SCAN 5004 FRL Height to the beginning of flue connecting piece at top outlet Centre of fresh air intake - Inside measure: 132 mm, Outside measure: 149 mm Flue conn. piece - Inside measure: 175 mm, Outside measure: 200 mm All measures are in mm *NB –...
PRODUCT REGISTRATIONUMBER All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S.
EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim- ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
REQUIREMENTS FOR CHIMNEY The chimney must have a minimum internal diameter of 190 mm and have a T400 designation, with G for the soot fire test. The length should be min. 5 metres. If you opt to connect the built-in stove with an elbow pipe, you should use a curved elbow, as this gives a better draught. If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the horizontal part can be cleaned through here.
BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL Building in the Scan 5004 FRL with radiation shields against a flammable wall protected by a fire wall. Flammable material Installation with an insulated, vertical flue pipe - structure/surround to ceiling Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick...
FRESH AIR BOX (ACCESSORY) A fresh air box is available as an accessory. For this box, you need a connection pipe (Ø 150 mm) which can be purchased in most D.I.Y.-stores. Drawing Friskluftsadapter Scan 5004 FRL 04-02-2019 95004093 Stove: Name: Date:...
The door is delivered without self-closing function (Bauart 1). If you want a self-closing door, you can remove a disc from the counterweight. First remove the screws and the cover plates at the rear of the fireplace. Drawing Låge med selvluk, Scan 5004 FRL Scan 5004 23-11-2017 95004031 Stove: Name:...
MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS (ACCESSORY) Dismount the screws on top of the fireplace B ( 1 : 4 ) Drawing Montage af varmeskjold, Scan 5004 FRL Scan 5004 Name: Date: 14-11-2017 95004023 Stove: number: Constructed/Changed by: Material: Weight:...
Page 17
MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS (ACCESSORY) Place the metal plate #2 at the rear of the stove Drawing Montage af varmeskjold, Scan 5004 FRL Scan 5004 14-11-2017 95004029 Stove: Name: Date: number: Constructed/Changed by: D ( 1 : 4 )
Fasten the metal frame with the six screws. Then mount the six magnets on the screws and place the convection grate on the magnets Montage af konventionsrist, Scan 5004 FR/FL og Scan 5004 95004039 TG.NR: NAVN: EMNE:...
LIGHTING We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and keeps the combustion process clean. See our video about correct firing on www.scan.dk or scan the QR-code. Please note that this Scan the QR-code video is only intended as a guide.
CONTINUOUS OPERATION It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane.
HANDLING OF THE FUEL SELECTING WOOD/FUEL You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives. PREPARATION The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st.
CHECKING THE STOVE Scan A/S recommends that you check your stove thoroughly after sweeping/cleaning. Check all visible surfaces for cracks. Check that all joints are tight and that the gaskets are correctly seated. Worn or deformed gaskets should be replaced.
A ( 0,13 : 1 ) DISPOSAL OF STOVE PARTS Steel/cast iron Send for recycling Glass Dispose of as ceramic waste Combustion chamber lining Vermiculite and chamotte are not recyclable. Dispose of as waste Baffle plates Vermiculite and chamotte are not recyclable. Dispose of as waste Gaskets Dispose of as waste CLEANING THE GLASS...
Page 32
D ( 1 : 2 ) Pull out the damper over the front glass, and then the two dampers at each side glass E ( 1 : 2 ) C ( 1 Rengøring af glas, Scan 5004 FRL 95004041 EMNE: TG.NR: 12-12-2017 DATO: VÆGT:...
Page 33
TROUBLESHOOTING SMOKE ESCAPING ¬ Damp wood ¬ Chimney not drawing properly ¬ Chimney is not properly dimensioned for the built-in stove ¬ Check if the smoke gas pipe/chimney are blocked ¬ Is the chimney the right height for its surroundings? ¬...
Page 34
You must quote your stove‘s product registration number when you contact us or your authorised Scan dealer with a warranty claim. The warranty covers all parts which in the opinion of Scan A/S require repair or replacement due to manufacturing or construc- tion error The warranty applies to the original purchaser of the product only, and is not transferable (except on prior sale).
Page 40
Product registration number Quote this number at all enquiries Edition: UK 95004500 10057052-P02 SCAN A/S Damsbovej 1 DK-5492 Vissenbjerg www.scan-stoves.com 25.11.2021...