  • Page 2 5004 FRL CONGRATULATIONS ON YOUR NEW SCAN BUILT-IN STOVE You have purchased a product by one of Europe’s leading manufacturers of wood-bur- ning stoves, and we are sure that you will have years of pleasure from your purchase. To make the best possible use of your stove, it is important that you follow our advice and instructions.
  • Page 3: Table Of Contents

    CONTENTS ¬ ¬ TECHNICAL DATA Installation Dimension sketch Scan 5004 FRL Safety Type plate Technical data and dimensions Product registrationumber ¬ ¬ ASSEMBLY Additional accessories Before building the insert Disposal of packaging Fresh air intake Load-bearing foundation Closed combustion system...
  • Page 4: Technical Data

    Any changes made to the product by the dealer, fitter or user could result in the product and safety functions not functioning as intended. The same applies to the fitting of accessories or extra equipment not supplied by Scan A/S. This could also be the case if parts that are necessary for the operation and safety of the stove are dismantled or removed.
  • Page 5: Technical Data And Dimensions

    Surface treatment Senotherm Dust @ 13% O mg/Nm Max. log length 40 cm No x @ 13% O mg/Nm Weight Scan 5004 FRL 210 kg Efficiency Weight Scan 5004 FRL Energy efficiency index 218 kg w/heat shield Energy efficiency class Flue conn.
  • Page 6: Dimension Sketch Scan 5004 Frl

    DIMENSION SKETCH SCAN 5004 FRL Height to the beginning of flue connecting piece at top outlet Centre of fresh air intake - Inside measure: 132 mm, Outside measure: 149 mm Flue conn. piece - Inside measure: 175 mm, Outside measure: 200 mm All measures are in mm *NB –...
  • Page 7: Type Plate

    PRODUCT REGISTRATIONUMBER All Scan built-in stoves are provided with a product registration number. Please make a note of this number at the rear page of this manual; you will always need to quote it when contacting your dealer or Scan A/S.
  • Page 8: Assembly

    EXISTING CHIMNEY AND PRE-FABRICATED ELEMENT CHIMNEY If you intend to connect your stove to an existing chimney, it makes sense to contact an authorised Scan dealer, or a local chim- ney sweep, for advice. These experts will also let you know if your chimney needs renovating.
  • Page 9: Requirements For Chimney

    REQUIREMENTS FOR CHIMNEY The chimney must have a minimum internal diameter of 190 mm and have a T400 designation, with G for the soot fire test. The length should be min. 5 metres. If you opt to connect the built-in stove with an elbow pipe, you should use a curved elbow, as this gives a better draught. If you connect the stove with a sharp elbow pipe, the cleansing lid must be placed in the vertical part so that the horizontal part can be cleaned through here.
  • Page 10: Building Into Flammable Material With Fire Wall

    BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL Building in the Scan 5004 FRL with radiation shields against a flammable wall protected by a fire wall. Flammable material Installation with an insulated, vertical flue pipe - structure/surround to ceiling Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick...
  • Page 11: Before Building The Insert

    BEFORE BUILDING THE INSERT DIMENSION: AREAL: Krog Iversen & Co A/S IMPORTANT! Before the insert is built in, the bolts in each the side of the insert should be removed. DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 5004\95004007.idw STI: Indbygning i brandmur Scan 5004 95004007 NAVN: EMNE: TG.NR:...
  • Page 12: Fresh Air Intake

    FRESH AIR BOX (ACCESSORY) A fresh air box is available as an accessory. For this box, you need a connection pipe (Ø 150 mm) which can be purchased in most D.I.Y.-stores. Drawing Friskluftsadapter Scan 5004 FRL 04-02-2019 95004093 Stove: Name: Date:...
  • Page 13: Door (Self-Closing)

    The door is delivered without self-closing function (Bauart 1). If you want a self-closing door, you can remove a disc from the counterweight. First remove the screws and the cover plates at the rear of the fireplace. Drawing Låge med selvluk, Scan 5004 FRL Scan 5004 23-11-2017 95004031 Stove: Name:...
  • Page 14: Clips For Norway (Large Rooms)

    M3 NR.: DIM.: AREAL: Scan A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 5004\95004008.idw STI: HEAT-STORAGE SYSTEM (ACCESSORY) Heat-storage stones are made from a special material with a high heat capacity. The stones are heated when the stove is on, re-releasing heat once it is off. This extends the time over which the stove remains warm.
  • Page 15: Mounting Of The Heat Shields/Convection Covers

    MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS (ACCESSORY) Dismount the screws on top of the fireplace B ( 1 : 4 ) Drawing Montage af varmeskjold, Scan 5004 FRL Scan 5004 Name: Date: 14-11-2017 95004023 Stove: number: Constructed/Changed by: Material: Weight:...
  • Page 16 MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS (ACCESSORY) Dismount the screws at the rear of the stove Drawing Montage af varmeskjold, Scan 5004 FRL 14-11-2017 95004026 Name: Date: number: Constructed/Changed by: Weight: Area: SCAN A/S DK-5492 Vissenbjerg© C ( 1 : 4 ) \Designs\Scan 5004\95004026.idw...
  • Page 17 MOUNTING OF THE HEAT SHIELDS/CONVECTION COVERS (ACCESSORY) Place the metal plate #2 at the rear of the stove Drawing Montage af varmeskjold, Scan 5004 FRL Scan 5004 14-11-2017 95004029 Stove: Name: Date: number: Constructed/Changed by: D ( 1 : 4 )
  • Page 18: Frames

    FRAMES (ACCESSORY) Baumaße / In-built dimension Indbygningsmål, Scan 5004 FRL Scan 5004 95004087 NAVN: EMNE: TG.NR: MATERIALE: VÆGT: DATO: 19-01-2018 SIGN: M3 NR.: DIM.: AREAL: Scan A/S DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 5004\95004087.idw STI:...
  • Page 19 FRAMES (ACCESSORY) Scan 5004 FRL Item nr. 50052628 • � • 95004061 Scan 5004 FRL FRAME, Item nr. 50052628 1 . 5 Scan 5004 FRL FRAME, Item nr. 50052628 Scan 5004 FRL FRAME, Item nr. 50052628 • • ·L 1 . 5 1 .
  • Page 20 FRAMES (ACCESSORY) • • Scan 5004 FRL Item nr. 50052629 4 33. 9 95004062 Scan 5004 FRL FRAME, Item nr. 50052629 1 . 5 Scan 5004 FRL FRAME, Item nr. 50052629 Scan 5004 FRL FRAME, Item nr. 50052629 • •...
  • Page 21: Braces

    Scan 5004 FRL INSTALLATION HOLDER, Item nr. 50052630 BRACES (ACCESSORY) • 41 7. 8 Scan 5004 FRL Item nr. 50052630 - N 1 "-.I -=:! � 1 : 1 1 : 1 1 : 1 C@)v • I � 3: 2 0 •...
  • Page 22 BRACES (ACCESSORY) Scan 5004 FRL INSTALLATION HOLDER, Item nr. 50052631 41 7. 8 Scan 5004 FRL Item nr. 50052631 � � � 1 : 1 1 : 1 1 : 1 I" • 3: 2 0 I • 95004064 Scan 5004 FRL INSTALLATION HO 41 7.
  • Page 23 Scan 5004 FRL INSTALLATION HOLDER, Item nr. 50052632 BRACES (ACCESSORY) Scan 5004 FRL Item nr. 50052632 '. 4 ..__ 11:1 l 'o - N 1 3: 2 0 3: 2 11:1 Scan 5004 FRL INSTALLATION HOLDER, Item nr. 50052632 l 'o...
  • Page 24: Convection Air

    Fasten the metal frame with the six screws. Then mount the six magnets on the screws and place the convection grate on the magnets Montage af konventionsrist, Scan 5004 FR/FL og Scan 5004 95004039 TG.NR: NAVN: EMNE:...
  • Page 25: Instructions For Use

    When lighting the fire, the combustion air should be fully open. Closed Open Spjældregulering Scan 5004 95004004 NAVN: EMNE: TG.NR: 11-08-2017 DATO: SIGN: MATERIALE: VÆGT: DIMENSION: AREAL: Krog Iversen & Co A/S A ( 1 : DK-5492 Vissenbjerg© C:\Working Folder\Designs\Scan 5004\95004004.idw STI:...
  • Page 26: Instructions For Heating

    LIGHTING We recommend the use of fire lighters, or similar products, which are available from your Scan dealer. Using fire lighters helps light the wood more quickly and keeps the combustion process clean. See our video about correct firing on www.scan.dk or scan the QR-code. Please note that this Scan the QR-code video is only intended as a guide.
  • Page 27: Continuous Operation

    CONTINUOUS OPERATION It is important to obtain as high a temperature as possible in the combustion chamber. This results in best possible use of the stove and fuel, as well as achieving clean combustion. In this way you will avoid build-up of soot on the combustion chamber lining and glass pane.
  • Page 28: Selecting Wood/Fuel

    HANDLING OF THE FUEL SELECTING WOOD/FUEL You can use any type of wood as fuel. However harder woods, such as beech or ash, are generally better for heating, as they burn more evenly and create less ash. Other woods, such as maple, birch and spruce, are excellent alternatives. PREPARATION The best fuel is obtained where the tree has been felled and the wood sawn and split before May 1st.
  • Page 29: Sweeping The Chimney And Cleaning The Stove

    CHECKING THE STOVE Scan A/S recommends that you check your stove thoroughly after sweeping/cleaning. Check all visible surfaces for cracks. Check that all joints are tight and that the gaskets are correctly seated. Worn or deformed gaskets should be replaced.
  • Page 30: Gaskets

    Then place chamotte plate #2a and #2b B-B ( 1 : 20 ) D ( 1 : 6 ) Place baffle fitting #4 and the upper baffle plate #7 Drawing Brandkammerforing, Scan 5004 FRL Stove: Scan 5004 Name: Date: 08-12-2017...
  • Page 31: Disposal Of Stove Parts

    A ( 0,13 : 1 ) DISPOSAL OF STOVE PARTS Steel/cast iron Send for recycling Glass Dispose of as ceramic waste Combustion chamber lining Vermiculite and chamotte are not recyclable. Dispose of as waste Baffle plates Vermiculite and chamotte are not recyclable. Dispose of as waste Gaskets Dispose of as waste CLEANING THE GLASS...
  • Page 32 D ( 1 : 2 ) Pull out the damper over the front glass, and then the two dampers at each side glass E ( 1 : 2 ) C ( 1 Rengøring af glas, Scan 5004 FRL 95004041 EMNE: TG.NR: 12-12-2017 DATO: VÆGT:...
  • Page 33 TROUBLESHOOTING SMOKE ESCAPING ¬ Damp wood ¬ Chimney not drawing properly ¬ Chimney is not properly dimensioned for the built-in stove ¬ Check if the smoke gas pipe/chimney are blocked ¬ Is the chimney the right height for its surroundings? ¬...
  • Page 34 You must quote your stove‘s product registration number when you contact us or your authorised Scan dealer with a warranty claim. The warranty covers all parts which in the opinion of Scan A/S require repair or replacement due to manufacturing or construc- tion error The warranty applies to the original purchaser of the product only, and is not transferable (except on prior sale).
  • Page 35 NOTES...
  • Page 40 Product registration number Quote this number at all enquiries Edition: UK 95004500 10057052-P02 SCAN A/S Damsbovej 1 DK-5492 Vissenbjerg www.scan-stoves.com 25.11.2021...