8)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[ON]
Note
f The contrast synchronization function will operate when all of the following conditions are fulfilled.
g All the projectors to be linked are connected in a loop with the daisy chain connection. (Maximum 64 projectors)
g [MODE] on only one projector that is linked is set to [MAIN], and [MODE] on all other projectors are set to [SUB].
g [CONTRAST SYNC] on the projectors to perform the contrast synchronization is set to [ON].
g If all linked projectors have the [CONTRAST MODE] setting menu, the [CONTRAST MODE] setting is unified to [1] or [2], regardless of
the [CONTRAST SYNC] setting.
g If there is any projector that does not have the [CONTRAST MODE] setting menu, the [CONTRAST MODE] setting is unified to [1],
regardless of the [CONTRAST SYNC] setting.
f It is possible to set [CONTRAST SYNC] to [OFF] for the projectors that are linked but not to synchronize.
Setting the shutter synchronization function
1)
Press as to select [MULTI PROJECTOR SYNC].
2)
Press the <ENTER> button.
f The [MULTI PROJECTOR SYNC] screen is displayed.
3)
Press as to select [MODE].
4)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[MAIN]
[SUB]
f When anything other than [OFF] is selected, the diagnostic result is displayed in [LINK STATUS], indicating
if all the projectors including the projectors targeted for synchronization are correctly connected, and if
[MODE] or the [PICTURE] menu → [DYNAMIC CONTRAST] → [CONTRAST MODE] is correctly set.
[LINKED]
[NO LINK]
5)
Press as to select [SHUTTER SYNC].
6)
Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
[ON]
Note
f The shutter synchronization function will operate when all of the following conditions are fulfilled.
g All the projectors to be linked are connected in a loop with the daisy chain connection. (Maximum 64 projectors)
g [MODE] on only one projector that is linked is set to [MAIN], and [MODE] on all other projectors are set to [SUB].
g [SHUTTER SYNC] on the projectors to perform the shutter synchronization is set to [ON].
g If all linked projectors have the [CONTRAST MODE] setting menu, the [CONTRAST MODE] setting is unified to [1] or [2], regardless of
the [SHUTTER SYNC] setting.
g If there is any projector that does not have the [CONTRAST MODE] setting menu, the [CONTRAST MODE] setting is unified to [1],
regardless of the [SHUTTER SYNC] setting.
f It is possible to set [SHUTTER SYNC] to [OFF] for the projectors that are linked but not to synchronize.
178 - ENGLISH
Chapter 4 Settings — [PROJECTOR SETUP] menu
Select this item when the contrast synchronization function is not used.
Select this item when the contrast synchronization function is used.
Select this item when the contrast synchronization function and the shutter synchronization function
are not used.
Select this item when the contrast synchronization function or the shutter synchronization function is
used.
Set this item only on one of the linked projectors that becomes the synchronization source of the
shutter operation.
Select this item when the contrast synchronization function or the shutter synchronization function is
used.
Set this item in all the linked projectors excluding the projector set as the [MAIN].
All the projectors are correctly connected, and correctly set. They are in the condition that the contrast
synchronization function or the shutter synchronization function can be used.
The projectors are not correctly connected, or not correctly set. Check the cable connection status
and the projector setting for each projector that is linked.
Select this item when the shutter synchronization function is not used.
Select this item when the shutter synchronization function is used.