Chapter 3: System planning

Wiring to Extend Network Sync

The following procedure can be used to extend network sync by one additional hop, as described under
Passing Sync in an Additional Hop
the co-located modules can be wired to pass the sync as follows:
1.
Connect the GPS Utility ports of the co-located modules using a sync cable with RJ-11 (for 450)
or RJ-45 (for 450i/450m) connectors.
2.
Set the Sync Input parameter on the Configuration page of the co-located AP or BH timing
master to AutoSync.
3.
Set the Device Type parameter on the Configuration page of the co-located AP or BH timing
master to Remote.
4.
Set the Sync Output to Aux Port parameter on the Configuration page of the co-located AP or
BH timing master to Disabled.
5.
Set the UGPS Power parameter on the Configuration page of the co-located AP or BH timing
master to Disabled.
6.
Set the Frame Timing Pulse Gated parameter on the Configuration page of the co-located SM or
BH timing slave to Enable.
Note
This setting prevents interference if the SM or BH timing slave loses sync.

Figure 69 Co-located AP or BH timing master Sync Setting configuration

on page 3-60. When a co-located module receives sync over the air,
3-63