PART II: INSTALLATION
Suntec TA..
Oil viscosity
Oil temperature
Min. suction pressure
Max. suction pressure
Max. return pressure
Rotation speed
1. Inlet G1/2
2. To the nozzle G1/2
3. Return G1/2
4. Pressure gauge port G1/4
5. Vacuum gauge port G1/4
6. Pressure governor
Connecting the oil flexible hoses to the pump
To connect the flexible oil hoses to the pump, proceed as follows, according to the pump provided:
1
remove the closing nuts A and R on the inlet and return connections of the pump;
2
screw the rotating nut of the two flexible hoses on the pump being careful to avoid exchanging the lines: see the arrows marked
on the pump.
For further information, refer to the technical documentation of the pump.
.
Diesel filters
5
6
7
(*) Supplied per pilot diesel fuel if present
3 ÷ 75 cSt
0 ÷ 150°C
- 0.45 bar to avoid gasing
5 bar
5 bar
3600 rpm max.
Suntec T+TV
R
A
Item
Note
20151PE (*)
-
20201PL (*)
-
GA70501
-
Suntec TA
A
R
Connection
Max. operating
pressure
3/8"
1 bar
3/8"
1 bar
1"
4 bar
26
Max. operating
Filtering
temperature
degree
100 μ
-20, 60 °C
100 μ
-20, 60 °C
100 μ
90 °C
Protec-
tion
-
-
IP65