Compaq ProLiant 850R Setup And Installation Manual page 81

Hide thumbs Also See for ProLiant 850R:
Table of Contents

Advertisement

3-30
Installing Hardware Options
SCSI ID Settings for Compaq Hard Drives
The following chart provides the SCSI ID jumper settings for
Compaq SCSI hard drives.
Installing Mass Storage Devices
Hard drives may be installed into drive bays 2 and 3, but these positions are
more often used for devices requiring user access.
Either a 1.6" or 1" height drive may be installed into a 1.6" height bay.
Installing a Tape Drive or CD-ROM drive
in Bay 3
1.
Remove the server cover. Refer to the "Removing a Server Cover"
section discussed in Chapter 2 for instructions on powering down the
server, disconnecting cables, and removing the server from the rack.
2.
Remove the front bezel.
3.
Locate the black guide screw installed on the the front of the chassis.
4.
Remove two black guide screws from the chassis and install them, (one
per side) in the mounting holes on the optional drive.
5.
Insert the drive into Bay 3.
Table 3-2
SCSI ID Settings
SCSI ID
Bit 2
6
ON
5
ON
4
ON
3
OFF
2
OFF
1
OFF
0
OFF
Bit 1
Bit 0
ON
OFF
OFF
ON
OFF
OFF
ON
ON
ON
OFF
OFF
ON
OFF
OFF

Advertisement