Data Channel Modules
Module Installation
With the exception of the power supply modules, all plug-in modules have an insertion and
extraction tab on the bottom of the front panel.
1. To install a plug-in module, insert the module into its slot with the GDC logo on top, then slide
it in until it makes contact.
2. Pull down the insertion/extraction tab and firmly push the module in until it seats in the rear
connectors.
3. To remove a plug-in module, pull down the insertion/extraction tab to unseat the module, then
pull on the tab.
Installation Restrictions
Any module may be installed in any slot, with the following restrictions:
•
Assignment of modules to slots must be that of the configuration on the TMS Controller or
OCM-1000 Point-to-Point Controller.
•
Rear panel Zone 1 (top) and Zone 3 (bottom) connector panels must meet the module
requirements.
•
The X1 jumpers must be in the correct position.
•
For maximum system reliability, we recommend that a module be removed from the currently
active TMS configuration before it is extracted from its slot.