Voice Modules (VCMs & DPVs)

DPV Options

Examine the module by checking the option headers on the modules.
describes the headers on the dual private voice channel modules. The configuration is set at the
factory to match your network operation. The headers are shown in their normal or default (factory
shipped) positions.
You need to check these settings when you first install the unit. You need not repeat the procedure
unless you change your network. When you are satisfied that the option settings are correct, install
the modules in the enclosure or shelf following the directions below:
With the exception of the power supply modules, all plug-in modules have an insertion and
extraction tab on the bottom of the front panel.
To insert/remove a plug-in module:
1. Insert the module into its slot with the GDC logo on top, then slide it in until it makes contact.
2. Pull down the insertion/extraction tab and firmly push the module in until it seats in the rear
connectors.
3. To remove a plug-in module, pull down the insertion/extraction tab to unseat the module, then
pull on the tab.