U039 Start position of rotation
Set start position from neutral pedal potision. (Pedal Stroke)
U040 Start position of acceleration
Set accelerating position from neutral pedal position. (Pedal Stroke)
U041 Start position of lifting of presser foot
Set work clamp lift position from neutral pedal position. (Pedal Stroke)
U042 Start position of lowering of presser foot
Set work clamp fall position from neutral pedal position. (Pedal Stroke)
U043 Start position of thread trimming
Set thread triming starting position from neutral pedal position. (Pedal Stroke)
U044 Position that maximum sewing speed is reached
Set maximum speed reaching position from neutral pedal position. (Pedal Stroke)
U045 Pedal neutral-position correction value
Set neutral position of pedal sensor.
U047 Presser-foot lift finishing position
The position to which the presser foot goes up when the back part of the pedal is
depressed to its first step. (1st-step spring position)
U048 Function of lifting the presser foot by depressing the pedal
Whether or not the presser-foot lifting operation is carried out by depressing the
back part of pedal is set.
0: No operation / 1: Operation
U049 Presser foot lowering time
Time to lower the presser foot is set.
U051 Correction of turning-ON of reverse feed stitching (at start)
U052 Correction of turning-OFF of reverse feed stitching (at start)
U053 Correction of turning-OFF of reverse feed stitching (at end)
U054 Standby time until the presser foot starts going up
Time to be elapsed from the moment the pedal is depressed to the 1st step to the
moment the presser foot starts going up.
U056 Reverse-rotation needle-up after thread trimming
The initial value differs with the machine head.
0: Reverse-rotation needle-up is not performed / 1: Reverse-rotation needle-up is
performed
U058 Needle bar home position retaining function
The retaining function retains the needle bar at upper or lower stop position. The
initial value varies with the machine head.
0: Disabled / 1: Enabled; Weak retaining force / 2: Enabled; Medium retaining force
/ 3: Enabled; Strong retaining force
U059 Selection of revere feed stitching (at start) operation
0: By manually operating the pedal, etc. / 1: According to the preset reverse feed
sewing speed
U060 Stop after reverse feed stitching (at start)
The stop function stops the sewing machine temporarily regardless of the operat-
ing status of the pedal.
0: OFF / 1: ON
U064 Sewing speed at the start of reverse feed stitching (at end)
Item
– 82 –
Setting range
Unit
10 to 1000
10 to 1000
-500 to -10
10 to 500
-1000 to -100
10 to 15000
-150 to 150
-1000 to -100
0 to 1
0 to 500
ms
-50 to 50
Degree
-50 to 50
Degree
-50 to 50
Degree
0 to 200
ms
0 to 1
0 to 3
0 to 1
0 to 1
150 to 1000
sti/min

Advertisement