2-9. Connecting the cords

DANGER :
1. To prevent personal injuries caused by electric shock hazards or abrupt start of the sewing machine,
carry out the work after turning OFF the power switch and a lapse of 5 minutes or more.
2. To prevent accidents caused by unaccustomed work or electric shock, request the electric expert or
engineer of our dealers when adjusting the electrical components.

2-9-1. Connecting the cords coming from the sewing machine

CTL PWB
PWR PWB
CN30
B
A
Fig. 3
White
3P
CN34
White
9P
CN30
Brown
CN32
60P
White
CN36
18P
White
CN37
4P
White
15P
CN38
White
4P
CN20
White
6P
CN21
White
CN22
6P
CN37
CN58
CN38
CN21
Loosen four setscrews ❷ of control box cover ❶ .
1)
Remove control box cover ❶ .
2)
Connect the cords to the respective connectors
on CTL PWB, PWR PWB. (Fig. 1)
Secure cord ❺ of pedal sensor with setscrew ❻
and cord clamp ❼ . (Fig. 2)
Securely fix the cords to be connected to
CN20, CN21 and CN22 with cable clamp ❸ .
Check the connector markers of CN21 and
CN22 to prevent improper connection.
Fix green/yellow ground wire ❹ at position A of
3)
the control box with a screw (Fig. 3). In addition,
for the EU type models, fix the cable (Black) at
screw B with a screw.
CN36
CN34
CN20
CN22
Fig. 1