The Function Group Number Is Used For The Identification Of Parameters, And Displayed In Alphanumeric Order - Mitsubishi Electric FR-CC2-H315K Instruction Manual

Table of Contents

Advertisement

5.1.2
The function group number is used for the
identification of parameters, and displayed in
alphanumeric order.
A parameter identification number shown on the PU can be switched from a parameter number to a function group number.
As parameters are grouped by function and displayed by the group, the related parameters can be set continually at a time.
 Changing a parameter identification number to a function group number
Pr.MD setting
0
The setting of parameter identification number remains the same as the last setting.
1
The parameter number is used for the identification of parameters, and displayed in numerical order.
2

The function group number is used for the identification of parameters, and displayed in alphanumeric order.

Operating procedure
1.
Turning ON the power of the converter unit
The operation panel is in the monitor mode.
2.
Selecting the parameter setting mode
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
3.
Selecting the parameter
Turn
until "
Press
to confirm the selection. The setting "
4.
Selecting the use of the function group number
Turn
to change the set value to "
setting. "
" and "
 Selecting a parameter by function group number to change its setting
The following shows the procedure to change the setting of P.M101 (Pr.774) Operation panel monitor selection 1.
Operating procedure
1.
Turning ON the power
The operation panel is in the monitor mode.
2.
Selecting the parameter setting mode
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
3.
Enabling the function group selection
Press
several times until "
4.
Enabling the function group selection
Turn
until "
"
of monitor parameter 1.
5.
Selecting a parameter
Turn
until "
display the present set value. "
" (Group parameter setting) appears.
" (function group number). Press
" are displayed alternately after the setting is completed.
" (monitor parameter 1) appears. Press
" will appear, which shows that the operation panel is ready for selection of a number in the group
" (P.M101 Operation panel monitor selection 1) appears. Press
(initial value)" appears.
Description
" (initial value) will appear.
" appears. Parameter groups can now be selected.
to select the Group parameter
to confirm the selection.
5. PARAMETERS
5.1 Parameter List
1
2
3
4
5
6
7
8
9
10
to
83