Mitsubishi Electric FR-CC2-H315K Instruction Manual page 131

Table of Contents

Advertisement

Item
Parameter clear / All
Write
parameter clear
Read
Parameter
Write
Read
Link parameter
extended setting
Write
Inverter model
Read
Capacity
Read
*1
Refer to
page 121
*2
Turning OFF the power supply while clearing parameters with H5A5A or H55AA returns the communication parameter settings to the initial
settings.
NOTE
• Set 65520 (HFFF0) as a parameter value "8888" and 65535 (HFFFF) as "9999".
• For the instruction codes HFF, HEC, and HF3, their values once written are held, but cleared to zero when a converter reset
or all clear is performed.
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
130
5. PARAMETERS
5.7 (N) Communication operation parameters
Read/
Instruction
write
code
All parameters return to initial values.
Whether to clear communication parameters or not can be selected
according to the data.
• Parameter clear
H9696: Parameters including communication parameters are cleared.
H5A5A: Parameters other than communication parameters are
cleared.
• All parameter clear
H9966: Parameters including communication parameters are cleared.
HFC
H55AA: Parameters other than communication parameters are
cleared.
For the details of whether or not to clear parameters, refer to
When a clear is performed with H9696 or H9966, communication related
parameter settings also return to the initial values. When resuming the
operation, set the parameters again.
Performing a clear will clear the instruction code HEC, HF3, and HFF
settings.
Only H9966 and H55AA (All parameter clear) are valid when a password
is registered (refer to
H00 to H63
Refer to the instruction code
values as required. When setting Pr.100 and later, the link parameter
H80 to HE3
extended setting must be set.
H7F
Parameter settings are changed (extended) according to the settings.
For details of the settings, refer to the instruction code
HFF
The inverter model name can be read in ASCII code.
"H20" (blank code) is set for blank area.
H7C
Example) For "FR-CC2-H":
H46, H52, H2D, H43, H43, H32, H2D, H48, H20, H20...H20
The capacity in the converter model can be read in ASCII code.
Data read is displayed in increments of 0.1 kW.
H7D
"H20" (blank code) is set for blank area.
Example) 315K..."3150" (H20, H20, H33, H31, H35, H30)
for data formats (A, A1, B, C, C1, D, E, E1, E2, E3, F).
Data description
*2
*2
page
90).
(page
182) and write and/or read parameter
Number of data
digits (format)
4 digits (A and C/D)
page
182.
4 digits (B and E/D)
4 digits (A and C/D)
2 digits (B and E1/D)
2 digits (A1 and C/
(page
182).
D)
20 digits (B and E3/
D)
6 digits (B and E2/D)
*1

Advertisement

Table of Contents
loading

Table of Contents