Operating Mode Description - MPP Solar LVX 6048 User Manual

Inverter / charger
Table of Contents

Advertisement

Secondary CPU version checking.

Operating Mode Description

Operating mode
Standby mode
Note:
*Standby mode: The inverter
is not turned on yet but at
this time, the inverter can
charge battery without AC
output.
*Power saving mode: If
enabled, the output of
inverter will be off when
connected load is pretty low
or not detected.
Line mode
Line mode
Secondary CPU version 00020.21
Behaviors
No output power, solar
or
utility
charger
available
Output
power
from
utility.
Charger
available
Output
power
from
utility.
Charger
available
23
LCD display
Battery is charged by utility.
Battery is charged by PV energy.
Battery is charged by utility and PV energy.
Battery is charged by PV energy and feed PV energy to
grid.
No charging.
Utility charges battery and provides power to load.
Utility and battery power provide power to load.
PV energy, battery power and utility provide power to
load.