SPECIFICATIONS

MODEL
RATED OUPUT POWER
PV INPUT (DC)
Max. PV Power
Max. Input voltage
(Maximum PV open voltage)
Max. DC Power MPPT range
Working MPP range
Max. DC Input current / per string
Number of MPP Tracker
GRID-TIE OPERATION
GRID OUTPUT (AC)
Nominal Output Voltage
Feed-in Grid Voltage Range
Feed-in Grid Frequency Range
Nominal Output Current
Power Factor Range
Maximum Conversion Efficiency (DC/AC)
OFF-GRID, HYBRID OPERATION
GRID INPUT
Acceptable Input Voltage Range
Frequency Range
Rating of AC Transfer Relay
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage
Output Waveform
Efficiency (DC to AC)
BATTERY & CHARGER
Nominal DC Voltage
Maximum Charging Current (from Grid)
Maximum Charging Current (from PV)
Maximum Charging Current
GENERAL
Dimension, D X W X H (mm)
Net Weight (kgs)
INTERFACE
Parallel-able
Communication
ENVIRONMENT
Humidity
Operating Temperature
LVX 6048
6000W
6000W
450 VDC
222 VDC~430 VDC
120 VDC~430 VDC
27A
1
110-120VAC (L-N) / 220-240VAC (L1-L2)
93.5~126.5 VAC For 110 Vac model
102~138 VAC For 120 Vac model
57 Hz ~63 Hz
27.3A (for 110VAC)
25A (for 120VAC)
>0.99
95%
65 - 140 VAC (Appliances) or 95 - 140 VAC (UPS)
50 Hz/60 Hz (Auto sensing)
40A
110-120VAC (L-N) / 220-240VAC (L1-L2)
Pure Sine Wave
93%
48 VDC
120A
120A
120A
593.6 x 365 x 138.4
26
Yes
RS232/Dry-Contact/Wi-Fi
0 ~ 90% RH (No condensing)
-10°C to 50°C
27