Notes
1. When the ribbon near end detection is enabled, the error LED blinks at a 1-second interval (ON for 500 msec.
OFF for 500 msec.) while the printer is in a ribbon near end state.
2. When there is command error in received commands, up to 42 bytes of error command, starting from the
command code, are shown on 3
(However, [LF] and [NUL] are not displayed. Also, 43bytes and later are not displayed.)
Display example
SYNTAX ERROR
PC00;0050,0020,1,1,A,
00,B,+00000000011=pri
(Example 1)
[ESC] PC001;0A00,0300,2,2,A,00,B [LF][NUL]
LCD
(Example 2)
[ESC]T20G30[LF][NUL]
LCD
(Example 3)
[ESC] PC002;0100,0300,15,15,A,00,00,J0101,+000000000A,Z10,P1[LF][NUL]
LCD
3. When a command error is displayed, the code other than 20H - 7FH and A0H - DFH is displayed as "?"
(3FH).
4. The battery check does not work when the printer is being reset and the RTC is not installed.
5. It is necessary to follow the procedure below to use RTC function under a low battery condition:
Turn off the printer power while the printer is in an error state. Start the printer in the system mode, set the
date and time for the RTC again, then reset the printer to place the printer in online state.
* The printer can print the programmed date and time until it is turned off.
rd
th
and 4
lines of the LCD.
Help▶
Command error
Command error
PC001;0A00,0300,2,2,A
,00,B
Command error
Command Error
T20G30
Command error
PC002;0100,0300,15,15
,A,00,00,J0101,+00000
34
Command error

Advertisement