Installation - Pilz PSEN sl-1.0p 2.2 Operating Manual

Hide thumbs Also See for PSEN sl-1.0p 2.2:
Table of Contents

Advertisement

BA PSEN sl­1.0p 1.1/1.1 VA/2.1/2.2
}
A maximum of 8 learning procedures are possible.
PSEN sl­1.0 2.2
The first corresponding actuator to be detected by the safety switch (see Technical details:
System with normal actuator [
mechanical data) is automatically taught in as soon as it is brought into the response range.

Installation

}
When installing make sure you comply with the requirements of DIN EN 1088.
}
The safety gate system can be installed on left or right­hinged swing gates or on sliding
gates.
}
The safety switch and actuator should be installed opposite each other in parallel.
}
The actuator should be secured permanently using safety screws or rivets.
Operating Manual BA PSEN sl­1.0p 1.1/1.1 VA/2.1/2.2
21909­EN­09
NOTICE
The actuator must not be removed during the learning procedure.
INFORMATION
This actuator cannot be retaught on the same safety switch.
 25], System with free­moving actuator [
NOTICE
No other actuator may be taught in once this actuator has been taught.
WARNING!
Potential loss of safety function due to gross manipulation
Depending on the application, serious injury or death may result.
Use appropriate installation measures to prevent
– The wiring being modified.
– A short circuit being generated on the connector.
– The possibility of using a second actuator to open the safety gate.
 28], under