Connection To Evaluation Devices - Pilz PSEN sl-1.0p 2.2 Operating Manual

Hide thumbs Also See for PSEN sl-1.0p 2.2:
Table of Contents

Advertisement

BA PSEN sl­1.0p 1.1/1.1 VA/2.1/2.2
The wire colour also applies for the cable available from Pilz as an accessory.
Connection to evaluation devices
Make sure that the selected evaluation device has the following properties:
}
Dual­channel with feasibility monitoring
}
OSSD signals are evaluated
Connection diagram, single connection
Operating Manual BA PSEN sl­1.0p 1.1/1.1 VA/2.1/2.2
21909­EN­09
Actuator
S11
S31
12
O1 (ST)
I1 (FS)
FS: Failsafe
ST: Standard
24 V 0 V
S21
Receiver
A1
A2
22
I2 (FS)
Evaluation device
A1
A2
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psen sl-1.0p 1.1 vaPsen sl-1.0p 2.1Psen sl-1.0p 1.1

Table of Contents