User's Manual | ACOM 06AT | Automatic Antenna Tuner and Switch
- Manually - by pressing the
by changing the antenna with the ANT button (only if more than one antenna was declared for the operating
frequency (see section
6.1 ANTENNA ASSIGNMENT Menu
The frequency segment (boundaries of validity of the current tuning) is numerically indicated on the basic
screen of the amplifier, above the tuner setting area. If the new frequency is outside the current frequency
segment, a quick tuning will be performed.
If the tuning found in memory is too old, the operator will see the message
Please, see Sections
4.4 Quick Tuning and Non-Volatile Memory

4.7. Specific of Operation in TRANSMISSION Mode

Under no circumstances should operation with antenna output SWR above 10:1 be
allowed!
In many cases, the tuner may be able to handle SWR even higher than 3:1 at the antenna output, but if the
protection for antenna overcurrent, overvoltage, forward or reflected power is activated, the operator
should reduce power input to the tuner (e.g., transceiver excitation).

4.8. Power Reduction at Overload

When matching of loads with SWR above 3:1 (up to 10:1) is possible, the maximum allowed tuner power
must be reduced gradually as per
October 2022
SEGMENT or SEGMENT
). The last used antenna is memorized.
WARNING: TUNING OUTDATED
NOTICE
Table 8-1 | Maximum input power of the tuner as function of the antenna SWR
S e c t i o n STARTING UP AND MAIN FUNCTIONS | Page 35 of 70
button (unless there is an active CAT) or
.
and
6.2.8 Aging and Refreshing of Settings
.
.