6.4.1. Voltage and Current at the Antenna Output
The antenna voltage and current are indicated in root-mean-square (rms) values.
They should not exceed:
ANTENNA VOLTAGE < 500 V (rms);
ANTENNA CURRENT < 10 A (rms).
6.4.2. Reflected Power, Forward Power and SWR at Antenna Output
The reflected power, forward power and SWR should not exceed:
ANTENNA REFLECTED POWER < 400 W;
ANTENNA FORWARD POWER < 1600 W;
ANTENNA SWR < 10:1.
Note that at SWR>1:1 at the tuner output, the forward power will exceed the tuner input power by the value
of the power reflected from the antenna. Therefore, it would be normal, e.g., at ANTENNA SWR=3:1, and
input power from the amplifier 1000 W, to measure:
ANTENNA FORWARD POWER = 1250 W and
ANTENNA REFLECTED POWER = 250 W
at the antenna output.
6.4.3. Power Supply Voltage and Temperature in the Tuner Unit
These two values should be within the following ranges:
ATU PS VOLTAGE = 22 ... 30 VDC;
ATU TEMPERATURE = -40...+65 °C (-40...+150 °F).
6.4.4. Tuner Working Hours
This is the number of hours during which the tuner has been powered.
October 2022