4. Troubleshooting
► Error Code
S1–1313
► Error message
The clock became initial time. Set a time again.
► Symptom
Saved time is invalid
► Troubleshooting method
1) Set up the time and reboot the machine.
a) Select "Machine Setup" on touch screen.
b) Select "General Setting".
c) Select "Date and Time" and set the time.
2) If the problem persistss, check the following.
a) Remove the rear cover.
(Refer to 3.3.2 Rear Cover)
b) Remove the fax holder from the main board.
c) Measure the voltage of the battery. If the battery is normal, the measured value is over 3V.
3) If the battery is normal, replace the main board(JC92–02429A).
4-165