Weekly; Monthly; Semi-Annually (More Often If Conditions Dictate) - Follett Symphony Plus 50 Series Installation, Operation And Service Manual

Ice and water dispensers
Hide thumbs Also See for Symphony Plus 50 Series:
Table of Contents

Advertisement

Weekly

§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser .
Dispenser drain pan and drain line
1. Pour 1 gal . (3 .8 L) of hot tap water into drain pan to flush drains .
Splash panel front, SensorSAFE infrared dispensing
1. Deactivate dispensing by pressing and releasing clean switch located on left side of unit under top front
cover .
2. Clean lens and splash panel front using a soft cloth and mild, non-abrasive, non-chlorine based cleaner .
3. Reactivate dispensing by pressing and releasing clean switch again .

Monthly

§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser .
Condenser (air-cooled ice machine only)
1. Use a vacuum cleaner or stiff brush to carefully clean condenser coils of lint and debris to ensure optimal
performance .

Semi-Annually (more often if conditions dictate)

§ A cleaning/descaling and sanitizing procedure should always include both the ice machine and dispenser .
§ Icemaking system can be cleaned/descaled in place .
§ Wear rubber gloves and safety goggles (or face shield) when handling cleaner or sanitizer mixtures .
§ Use only Follett approved cleaners .
§ It is a violation of Federal law to use Cleaning or Sanitizing solution in a manner inconsistent with their labeling .
§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser .
Cleaning solution: Following manufacturer's instructions, mix cleaning solution of 1 gal . (3 .8L) 100 F (38 C)
Sanitizing solution: Following manufacturer's instructions, mix a sanitizing solution of 1 gal . (3 .8 L) 100 F (38 C)
Cleaning & Sanitizing Tool Checklist
§ (2) 1 .5 Gallon (or larger) Plastic Buckets
§ (2) clean cloths
§ Sanitary gloves
§ Safety Glasses
§ (2) Sani-Sponge™ (P/N 00131524 - single sponge)
§ (1 ) Packet of SafeCLEAN™ (P/N 00132001 - 24 packets)
§ 1 .6 fl oz . of Nu-Calgon IMS-II or IMS-III Sanitizer (P/N 00979674 - 16 fl . oz . bottle)
12
water and 7 oz . (198 g) (one 7 oz . packet) of Follett SafeCLEAN™ ice machine cleaner/
descaler (P/N 00132001) .
water and 1 .6 oz . (48 ml) Nu-Calgon IMS-II or IMS-III Sanitizer (P/N 00979674) .
CAUTION!