SensorSafe Board guide
LEDs, when illuminated, indicate the following: PWR
(board power), CLN (clean button pressed WTR and
WM outputs disabled), ICE (ice dispensing activated),
WTR (water dispensing activated) .
Terminals: L1 (incoming power, hot), L2 (neutral
terminals), WTR (power terminal for water solenoid),
WM (power terminal for wheelmotor), CLN (terminals
for clean cycle switch) .
Note: SOL terminal not used in 12 series dispensers .
Lens/sensor troubleshooting
1. Turn dispenser power switch off and remove slash panel .
2. Disconnect wires from WTR and WM terminals on board .
3. Gently remove sensor/mounting block from splash panel .
4. Inspect lens and sensor, clean if necessary .
5. Restore dispenser power and test sensor by passing hand in front of sensor .
6. If LED on board turns on, sensor is operational . Re-assemble dispenser .
7. If LED does not come on switch sensor leads on board and retest .
8. If opposite Led comes on – replace defective board .
9. If opposite Led does not come on – replace defective sensor .

Ice machine removal instructions

§ Disconnect power to unit before putting hands or arms in storage area or attempting any repair or service to
equipment .
Fig. 18 – All models
1. Dispense all ice and remove front cover
(Fig. 18) .
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
Fig. 17
L1
SOL
WTR
CAUTION!
Fig. 19 – All models
2. Remove splash panel (Fig. 19) .
GND
PWR
CLN
WM
ICE