Available Functions; Wide Area Measurement Functions; Back-Up Protection Functions - Hitachi Relion RES670 Commissioning Manual

Phasor measurement unit
Hide thumbs Also See for Relion RES670:
Table of Contents

Advertisement

1MRK 511 409-UUS Rev. K
Section 3
3.1

Wide area measurement functions

IEC 61850 or function
name
PMUCONF
PMUREPORT
PHASORREPORT1
PHASORREPORT2
PHASORREPORT3
PHASORREPORT4
ANALOGREPORT1
ANALOGREPORT2
ANALOGREPORT3
BINARYREPORT1
BINARYREPORT2
BINARYREPORT3
PMUSTATUS
3.2

Back-up protection functions

IEC 61850 or
ANSI
function name
Impedance protection
ZMBURPSB
68
OOSPPAM
78
Current protection
OC4PTOC
51_67
EF4PTOC
51N_67N
NS4PTOC
46I2
Table continues on next page
Phasor measurement unit RES670
Commissioning manual

Available functions

The following tables list all the functions available in the IED. Those functions that are
not exposed to the user or do not need to be configured are not described in this
manual.
ANSI Function description
Configuration parameters for C37.118 2011 and IEEE1344 protocol
Protocol reporting via IEEE1344 and C37.118
Protocol reporting of phasor data via IEEE 1344 and C37.118, phasors 1-8
Protocol reporting of phasor data via IEEE 1344 and C37.118, phasors 9-16
Protocol reporting of phasor data via IEEE 1344 and C37.118, phasors 17-24
Protocol reporting of phasor data via IEEE 1344 and C37.118, phasors 25-32
Protocol reporting of analog data via IEEE 1344 and C37.118, analogs 1-8
Protocol reporting of analog data via IEEE 1344 and C37.118, analogs 9-16
Protocol reporting of analog data via IEEE 1344 and C37.118, analogs 17-24
Protocol reporting of binary data via IEEE 1344 and C37.118, binary 1-8
Protocol reporting of binary data via IEEE 1344 and C37.118, binary 9-16
Protocol reporting of binary data via IEEE 1344 and C37.118, binary 17-24
Diagnostics for C37.118 2011 and IEEE1344 protocol
Function description
Power swing detection, blocking and unblocking
Out-of-step protection
1)
Directional phase overcurrent protection, four steps
Directional residual overcurrent protection, four steps
2)
Directional negative phase sequence overcurrent protection, four steps
© 2017 - 2022 Hitachi Energy. All rights reserved
Section 3
Available functions
GUID-F5776DD1-BD04-4872-BB89-A0412B4B5CC3 v1
GUID-5638298D-1D93-4E95-94D4-A5AB51AE3058 v1
Phasor
measurement
RES670
(Customized)
1
1-2
1-2
0-2
0-2
0-2
0-2
0-2
0-2
0-2
0-2
0-2
1
GUID-06D023C0-3F72-4D89-A0A5-F4B452234B7B v1
Phasor
measurement
unit
RES670
(Customized)
0-1
0-2
0-6
0-6
0-6
21