Press the ALARM key to reset current value.
Example: The calibrated pressure sources measure 25.00
inHg. The display console pressure reads 24.85 inHg.
Offset = 25.00 - 24.85 = 0.15 inHg
Note: The display console displays two different pressures:
absolute (measured) and relative (corrected to sea-level).
To compare pressure conditions from one location to another,
meteorologists correct the pressure to sea-level conditions.
Because the air pressure decreases as you rise in altitude, the
sea-level corrected pressure (the pressure your location would
be at if located at sea-level) is generally higher than your
measured pressure.
Thus, your absolute pressure may read 28.62 inHg (969 mb) at
an altitude of 1000 feet (305 m), but the relative pressure is
30.00 inHg (1016 mb).
The standard sea-level pressure is 29.92 in Hg (1013.2hpa).
This is the average sea-level pressure around the world.
Relative pressure measurements greater than 29.92 inHg
(1013.2hpa) are considered high pressure and relative
pressure measurements less than 29.92 inHg are considered
low pressure.
To determine the relative pressure for your location, locate an
official reporting station near from you (the internet is the best
source for real-time barometer conditions, such as the website
- 34 -

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC089 and is the answer not in the manual?

Questions and answers

Bob Valdez
March 9, 2025

How do I reset the indoor temperature setting on my sainlogic sc089 weather station.

1 comments:
Mr. Anderson
March 9, 2025

To reset the indoor temperature on the Sainlogic SC089 weather station, press and hold the MAX/MIN key for three seconds to clear all minimum and maximum values, including indoor temperature. After reset, the display will show the current values.

This answer is automatically generated

Table of Contents

Save PDF