Error code
E485
Number of times of basting unsetting error
In the case the number of times of basting is not set (OFF)
for "Basting+ Cloth cutting knife shape".
E486
Eyelet knife length error
Eyelet knife length is too short to form the shape in case of
eyelet shape.
E487
Eyelet shape length error
Eyelet shape length is too short to form the shape in case
of eyelet shape.
E488
Taper bar-tacking compensation error
When bar-tacking length is too short to form the shape in
case of taper bar-tacking shape.
Knife size error (at the time of plural motions of knife)
E489
When knife size is larger than cloth cutting knife size.
E492
Presser size over of basting
When stitching data of basting exceeds presser size.
E493
Presser size over of tie stitching at sewing end
When stitching data of tie stitching at sewing end exceeds
presser size.
Description
– 81 –
How to recover
Place of recovery
Possible to re-
(During individual sew-
cover by reset.
ing/cycle sewing)
Sewing data edit
screen
[S034] Basting stitch
(OFF/Number of times)
(During continuous
sewing)
Standard screen
Possible to re-en-
(During individual sew-
ter after pressing
ing/cycle sewing)
reset key.
Sewing data edit
screen
[S017] Eyelet knife
length
(During continuous
sewing)
Standard screen
Possible to re-en-
(During individual sew-
ter after pressing
ing/cycle sewing)
reset key.
Sewing data edit
screen
[S014] Eyelet shape
length
(During continuous
sewing)
Standard screen
Possible to re-en-
(During individual sew-
ter after pressing
ing/cycle sewing)
reset key.
Sewing data edit
screen
[S008] 2nd bar-tacking
length
(During continuous
sewing)
Standard screen
Possible to re-en-
(During individual sew-
ter after pressing
ing/cycle sewing)
reset key.
Sewing data edit
screen
[S002] Cloth cut length
(During continuous
sewing)
Standard screen
Possible to re-en-
(During individual sew-
ter after pressing
ing/cycle sewing)
reset key.
Sewing data edit
screen
[S040] Basting needle
entry compensation
(During continuous
sewing)
Standard screen
Possible to re-en-
(During individual
ter after pressing
sewing/cycle sewing)
reset key.
Sewing data edit
screen
[S067] Tie stitching at
sewing end width
(During continuous
sewing)
Standard screen