B. Good Faith Wall Surface / TV Guidelines
NOTICE: Surface temperatures listed above are taken with
a temperature measuring probe as prescribed by the test
standard used for appliance certification. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 °F (17 °C) or
more depending on the thermometer settings and material
characteristics being measured. Use appropriate finishing
materials that are able to withstand these conditions. For
additional finishing guidelines, see Section 10. Surface
temperatures will vary due to factors such as ceiling height,
room size, finishing materials and installation configuration.
For All Decorative Fronts Except Portrait
FIREPLACE
OPENING
Figure 2.1 Good Faith Wall Surface Temperatures Above
Appliance (All Fronts Except Portrait)
Portrait Decorative Front
FIREPLACE
OPENING
Figure 2.2 Good Faith Wall Surface Temperatures Above
Appliance (PORTRAIT Decorative Front Installed)
Heat & Glo • 6KX, 6KX-LP, 8KX, 8KX-LP Installation Manual • 2583-980 • Rev. C • 5/23
TO CEILING
140
°F
140°F
145
°F
30 in.
150
°F
24 in.
18 in.
165
°F
12 in.
6 in.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT
TO CEILING
150°F
150
°F
175
°F
24 in.
18 in.
185
°F
12 in.
6 in.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT
Optional Passive Heat Kit Installed
FIREPLACE
OPENING
Figure 2.3 Good Faith Wall Surface Temperatures Above
Appliance With Passive Heat Kit Installed
TO CEILING
90
°F
90°F
95
°F
30 in.
100
°F
24 in.
18 in.
115
°F
12 in.
6 in.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT