Installing A Television; Mantel And Wall Projections - Heat&Glo 6KX-CU Installation Manual

Table of Contents

Advertisement

B. Installing a Television
If installing a television (TV) above the appliance, see
Section 2.B.
C. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specified. Mantel MUST be fastened to wall
with no gaps.
• Framing closer than the minimums listed must be
constructed entirely of non-combustible materials (i.e.,
steel studs, concrete board, etc.).
• No gaps allowed between the wall and the bottom of the
mantel.
• Combustible mantel legs and wall projections may be
applied over the non-combustible board supplied with
the appliance. Follow guidelines as shown in the figures
below for mantels, mantel legs and wall projections.
• Measurement is taken from top/side of the opening, NOT
the top/side of the appliance.
Mantel requirements are shown in Figures 10.4-10.10.
Note: The Portrait decorative barrier fronts
have a unique set of mantel requirements.
Combustible Mantels
Note:
All measurements
in inches.
4
3
2-1/2
5
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6KX)
= 35-1/2 IN. (8KX)
Note: Measurement is taken from top of the opening,
Figure 10.4 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles or Painted Surfaces
Heat & Glo • 6KX, 6KX-LP, 8KX, 8KX-LP Installation Manual • 2583-980 • Rev. C • 5/23
66
TO CEILING
18
12
11
10
32
9
8
25
7
19
6
18
5
17
16
15
14
13
12
11
10
Combustible Mantels with Portrait Decorative Front
Note: All
measurements
5
in inches.
4
3
2-1/2
20
15
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6KX)
= 35-1/2 IN. (8KX)
Note: Measurement is taken from top of the opening,
Figure 10.5 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles (Portrait Fronts)
Combustible Mantels - Passive Heat Installed
Note:
All measurements
in inches.
12
2-1/2
5
Measurement from fireplace
opening to bottom of appliance:
= 33-1/2 IN. (6KX)
= 35-1/2 IN. (8KX)
Note: Measurement is taken from top of the opening,
NOT the top of the fireplace.
Figure 10.6 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - Passive Heat Kit
Installed
TO CEILING
18
12
11
10
42
9
35
8
7
29
6
28
27
26
25
24
23
22
21
TO CEILING
18
17
16
12
15
11
14
10
13
9
8
7
6
50

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents