Finishing

A. Facing Material
WARNING
Risk of Fire!
DO NOT apply combustible materials beyond the min-
imum clearances. Comply with all minimum clearanc-
es to combustibles as specified in this manual. Ma-
terials overlapping into non-combustible zones could
ignite and will interfere with air flow through decorative
barrier fronts.
• Metal front of appliance may be covered with non-
combustible materials only.
• Facing and/or finishing materials must not interfere
with air flow through decorative barrier fronts, removal
of decorative barrier fronts or access for service.
• Facing and/or finishing materials must never
overhang into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal gaps between the finished wall and appliance
top and sides using a 300 ºF minimum sealant. Refer
to Figure 10.1 and Figure 10.2.
• Finishing materials must be installed with no gaps
in order to prevent the escape of heat between the
finishing material and the wall. See Figure 10.1.
NOTICE: Surface temperatures around the appliance will
become warm while the appliance is in operation. Ensure
finishing materials used for all surfaces (floor, walls,
mantels, etc.) will withstand temperatures up to 190°F.
WARNING! Risk of Overheating! DO NOT allow gap
between finishing materials and front of appliance.
NON-COMBUSTIBLE
FINISHING MATERIAL
NO GAP ALLOWED
Figure 10.1 Finishing Material Installed
Heat & Glo • 6KX, 6KX-LP, 8KX, 8KX-LP Installation Manual • 2583-980 • Rev. C • 5/23
DRYWALL OR
WALL SHEATHING
MATERIAL
FACTORY-INSTALLED
NON-COMBUSTIBLE BOARD
FACING MATERIAL UP TO 1/2 IN. THICK
MAY BE COMBUSTIBLE - TOP AND SIDES
0 IN.
FACTORY-INSTALLED NON-COMBUSTIBLE BOARD
1-1/8 IN.
HIGH TEMPERATURE (300 ºF/ 149 ºC MIN.)
TOP AND SIDE SEAL JOINT
0 IN.
REMOVABLE SURROUND (SHADED AREA)
MAY BE COVERED WITH COMBUSTIBLE
OR NON-COMBUSTIBLE MATERIAL
inches
6KX
millimeters
inches
8KX
millimeters
Figure 10.2 Non-combustible Facing Diagram
WARNING! Risk of Overheating! DO NOT install
combustible or non-combustible flooring or hearth
material above top of bottom surround. Gap be-
tween bottom of decorative front and top of bottom
surround must be maintained for proper air flow.
FLOORING OR HEARTH MATERIAL
NOT ALLOWED
ABOVE TOP OF BOTTOM SURROUND
DECORATIVE BARRIER FRONT
REQUIRED AIR FLOW GAP
Flooring & Hearth Material (1-1/8 IN. MAX.)
Figure 10.3 Required Air Flow Gap
B
DO NOT REMOVE
A
0 IN.
A
B
40-7/8
41
1038
1041
42-7/8
48
1089
1219
65