LRF 3013 Integrator Manual
6.2.3
Software versions, hardware configuration and serial number
This command is used to read out the following system information:
Product type
Article number
Serial number
uC Firmware version
DSP firmware version
HW configuration
Each field ends with a carriage return, that is: in a terminal program each field will be displayed on a
separate line. Future FW releases may add new fields/lines to the command output.
Command format:
Software versions, hardware configuration and serial number
Table 2
Command Input
Input
>Iv1<CR>
>Iv<CR>
Output
Field/Line
Product
Article number
Serial number
uC FW version
DSP FW version
Detected HW
Document number: TML 913655 ver A
Confidential & Proprietary Safran Vectronix AG – All rights reserved
Value
Prod: LRF-MB-ModC -
910994<CR>
Article Num.: nn<CR>
Serial Num.: nn<CR>
uC FW: vWW.XX.YYkZZ
- Mmm dd yyyy<CR>
DSP FW: X.YY -
dd/mm/yy< CR>
HW: xx-yy-ww-zz<CR>
Description
Read out of SW versions, HW configuration and
serial number.
Description
LRF product type with PLM number
Article number:
"nn" is a decimal number with up to ten
digits (0 ≤ nn ≤ 2
Serial number:
"nn" is a decimal number with up to ten
digits (0 ≤ nn ≤ 2
Version of microcontroller firmware with compiling
date:
"WW", "XX", "YY", "k" and "ZZ" indicate the
firmware version as defined in RD1
"Mmm", "dd", "yyyy" is the compiling date
Version of DSP firmware with compiling date:
"X.YY" is the firmware version
"dd/mm/yy" is the compiling date
Detected HW:
"xx" : LRF-MB-ModC HW version
"yy" : 'Extension' board
"ww" : Transmitter board
"zz" : Receiver board
See PD3 for details about exact values.
32
-1)
32
-1)
Public: 13.03.2017