Built-In Self Test - Safran LRF 3013 Manual

Table of Contents

Advertisement

LRF 3013 Integrator Manual
Example
View in a terminal program
<>Iv<0D>
Prod: LRF-MB-ModC -
Article Num.:
4294967295<0D>
Serial Num.:
0<0D>
uC FW: v00.04.00B00 - Dec 11
DSP FW: 9.99 -
23/10/13<0D>
HW:
03-31-06-02<0D>
<
6.2.4

Built-In Self Test

Built-In Self Test
Table 3
Command Input
Input
>Tb1<CR>
Command Output
Char Num.
Value
1 to 5
BIST:
6
<space>
7 to 8
XX
9
<CR>
Example
Output
BIST: F3<CR>
BIST: FF<CR>
View in a terminal program
<>Tb1<0D>
BIST:
F7<0D>
<
Document number: TML 913655 ver A
Confidential & Proprietary  Safran Vectronix AG – All rights reserved
910994<0D>
2013<0D>
Description
It starts a self test sequence.
Description
Message description string
Separation space
Hex value representing tests' results (see table below).
End character
Description
5V and 7.5V power supplies failed their test.
All tests were successful.
Legend
Commands sent to the module are in black (hex values in
blue). Characters sourced by the module are in green (hex
values in red).
The hex value 0D is the carriage return.
Legend
Commands sent to the module are in black
(hex values in blue). Characters sourced
by the module are in green (hex values in
red).
The hex value 0D is the carriage return.
Public: 13.03.2017