5. Connecting
5.1. Preparing the connection
Always observe the following safety instructions:
•
Connect or disconnect only in the complete absence of line voltage
•
Take note the data concerning on the
overcurrent protection in installation.
•
Use only a screwdriver with appropriate head
Take note the suitability of the connecting cable
(wire cross-section, insulation, etc.).
You may use either solid conductor or flexible conductor.
In case of using flexible conductor use crimped wire end.
In case of mains connection the wire cross-section should be 1.0 mm2
(min.).
It's an important rule that the power cables and signal cables should
lead on a separate way.
Prepare the cable for the connection.
Strip approx. 6 mm insulation.
In case of using flexible cable, use crimped wire end.