Connecting The A 4578, A 4581 And A 4597 Remote Plates - Redback A 4565B Operating Manual

Evacuation controller
Table of Contents

Advertisement

3.6 CONNECTING THE A 4578, A 4581, A 4581V and A 4597 REMOTE PLATES
Connection is made to the A 4565B via standard Cat5e cabling as shown in Fig 3.6b. There are two RJ45 ports on the rear
of the A 4578, A 4581 and A 4597 wall plates, either of which can be used. Connection to the A 4565B is via the four
available RJ45 output ports.
Up to a maximum 16 wall plates can be cascaded together through use of the four RJ45 ports from the A 4565B.
Any combination of A 4578, A 4581 or A 4597 plates can be used together.
It is recommended that a maximum of four remote plates are connected to each output port.
(The maximum current draw on each port is 0.5amps)
NOTE: If more than 16 wall plates are required contact Altronics for configuration details.
CASCADING THE A 4578, A 4581 and A 4597 REMOTE PLATES
If more than one remote wall plate is required then the wall plates can be cascaded together with only one connection
back to the A 4565B required (see Fig 3.6b). A Maximum of 16 plates is recommended, (If more than 16 wall plates are
required contact Altronics for configuration details). There are four RJ45 ports on the rear of the A 4565B, any of which
can be used for connection to the wall plates.
REMOTE PLATE ID
Every A 4578, A 4581 and A 4597 remote plate must have a unique ID which is set by the DIP switches which are ac-
cessed on the rear of the wall plate. A maximum of 63 ID's are available. Fig 3.6a illustrates the DIP switch ID settings.
DIP Switches 7-8 are not used.
A record sheet has been supplied for recording these ID's for future use.
www.redbackaudio.com.au
Redback® A 4565B Evacuation Controller
DIP Switch Settings
2
3
ID
1
4
5
1
ON
OFF
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
OFF
3
ON
ON
OFF
OFF
OFF
4
OFF
OFF
ON
OFF
OFF
5
ON
OFF
ON
OFF
OFF
ON
6
OFF
ON
OFF
OFF
7
ON
ON
ON
OFF
OFF
8
OFF
OFF
OFF
ON
OFF
9
ON
OFF
OFF
ON
OFF
10
OFF
ON
OFF
ON
OFF
11
ON
ON
OFF
ON
OFF
12
OFF
OFF
ON
ON
OFF
13
ON
OFF
ON
ON
OFF
14
OFF
ON
ON
ON
OFF
15
ON
ON
ON
ON
OFF
16
OFF
OFF
OFF
OFF
ON
17
ON
OFF
OFF
OFF
ON
18
OFF
ON
OFF
OFF
ON
19
ON
ON
OFF
OFF
ON
20
OFF
OFF
ON
OFF
ON
21
ON
OFF
ON
OFF
ON
22
OFF
ON
ON
OFF
ON
23
ON
ON
ON
OFF
ON
24
OFF
OFF
OFF
ON
ON
25
ON
OFF
OFF
ON
ON
26
OFF
ON
OFF
ON
ON
27
ON
ON
OFF
ON
ON
28
OFF
OFF
ON
ON
ON
29
ON
OFF
ON
ON
ON
30
OFF
ON
ON
ON
ON
31
ON
ON
ON
ON
ON
32
OFF
OFF
OFF
OFF
OFF
DIP Switch Settings
ID
1
2
3
6
33
OFF
ON
OFF
OFF
34
OFF
ON
OFF
OFF
35
ON
ON
OFF
OFF
36
OFF
OFF
OFF
ON
37
OFF
ON
OFF
ON
38
OFF
OFF
ON
ON
OFF
39
ON
ON
ON
OFF
40
OFF
OFF
OFF
41
OFF
ON
OFF
OFF
42
OFF
OFF
ON
OFF
43
OFF
ON
ON
OFF
44
OFF
OFF
OFF
ON
OFF
45
ON
OFF
ON
46
OFF
OFF
ON
ON
47
OFF
ON
ON
ON
48
OFF
OFF
OFF
OFF
49
OFF
ON
OFF
OFF
OFF
50
OFF
ON
OFF
OFF
51
ON
ON
OFF
OFF
52
OFF
OFF
ON
53
OFF
ON
OFF
ON
OFF
54
OFF
ON
ON
OFF
55
ON
ON
ON
OFF
56
OFF
OFF
OFF
57
OFF
ON
OFF
OFF
58
OFF
OFF
ON
OFF
59
OFF
ON
ON
OFF
OFF
60
OFF
OFF
ON
61
OFF
ON
OFF
ON
62
OFF
OFF
ON
ON
63
OFF
ON
ON
ON
ON
Fig 3.6a
Redback® Proudly Made In Australia 19
4
5
6
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON

Advertisement

Table of Contents
loading

Table of Contents