Table 19 - Pressure Setup Menus - Honeywell SMV800 SmartLine User Manual

Multivariable transmitter
Hide thumbs Also See for SMV800 SmartLine:
Table of Contents

Advertisement

<Return>
Device DP Unit
Device SP Unit
Device MBT Unit
DP Damping sec
Pressure
Params
SP Damping sec
Transfer Function
(HART and DE only)
Filter Perform (HART and
Modbus only)
DP LRV
DP LRV
DP URV
DP URV
Set DP LRV
Set DP LRV
**
Set DP URV
Set DP URV
**
Active Cal Set
DP Factory
Cal **
Select Cal Set
SP LRV
SP LRV
SP URV
SP URV
Set SP LRV
Set SP LRV
**
Set SP URV
Set SP URV
**
Active Cal Set
(read only)
SP Factory
Cal ***
Select Cal Set
MBT LRV
MBT LRV (in
(Modbus
preferred unit)
only)
MBT URV
MBT URV (in
(Modbus
preferred unit)
only)
Revision 10
Table 19 – Pressure Setup Menus
Differential Pressure device variable
unit, Static Pressure device variable
unit, Meter body Temperature unit
Damping constant value for DP and
SP
Transfer function selection
(Linear/Square root)
Filter selection (Standard SOR / Fast
SOR)
The limit for the Lower Range Value is
###. ##
2X the Lower Range Limit (LRL) of the
Meter body
The limit for the Upper Range Value is
###. ##
2X the Upper Range Limit (URL) of
the Meter body
ATTENTION: Executing this service will set the Lower
Range Value (LRV) equal to the input pressure
ATTENTION: Executing this service will set the Upper
Range Value (URV) equal to the input pressure
Displays the calibration used by the transmitter.
Cal Set A
This selection allows the user to
Cal Set B
choose calibration set from drop-down
Cal Set C
menu,
Best Fit
The limit for the Lower Range Value is
###. ##
2X the Lower Range Limit (LRL) of the
Meter body
The limit for the Upper Range Value is
###. ##
2X the Upper Range Limit (URL) of
the Meter body
ATTENTION: This service will set the Lower Range
Value (LRV) equal to the input pressure
ATTENTION: This service will set the Upper Range
Value (URV) equal to the input pressure
Displays the calibration used by the transmitter.
Cal Set A
This selection allows the user to
Cal Set B*
choose calibration set from drop-down
Cal Set C**
menu,
Best Fit
The limit for the Lower Range Value is
###. ##
2X the Lower Range Limit (LRL) of the
Meter body
The limit for the Lower Range Value is
###. ##
2X the Lower Range Limit (LRL) of the
Meter body
SMV800 Transmitter User's Manual
Press  to enter
menu selection
 to execute
Press  to enter
menu selection
 to execute
Read only
Press  to enter
menu selection
Press
 and  to select
calibration type.
 to initiate
Press  to enter
menu selection
 to execute
Read only
Press  to enter
menu selection
Press
 and  to select
calibration type.
 to initiate
Press  to enter
menu selection
 to execute
Page 49