Nozzle installations
In the case of a material with good reflection properties (high dielectric constant, DK), the
sensor may be mounted on a nozzle. The background subtraction ("virtual echo learning")
feature can further reduce false echoes from nozzle openings.
Table 3-2
shows detail of the size limitations of the nozzle.
Nozzle Diameter
d(mm)
Page 10
Figure 3-5: nozzle specifications diagram
Table 3-2: nozzle specifications table
Maximum Nozzle Height h(mm)
83A
40
150
50
150
80
200
100
300
125
400
150
500
SLN 700 SmartLine NCR Level Transmitter User's Manual
82A 82B
82C 82D
83B 83C
83D 83E
NA
NA
150
NA
200
200
300
300
400
400
500
500
87A 87B
87C 87D
NA
NA
NA
300
400
500
Revision 1