Type Designation; Table 3-9. Type Designation - Advanced Energy Thyro-PX User Manual

Dc power controller
Hide thumbs Also See for Thyro-PX:
Table of Contents

Advertisement

®
Advanced Energy
Table 3‑8. Climatic specifications  (Continued)
Transportation
1
Non-condensing, no formation of ice
2
Operation at higher altitudes is possible with reduced current limits. From +1000 m to +2000 m
(+3281' to +6562'), the rated current is decreased by 1.5%/100 m (1.5%/328'). Contact AE Global
Services for operating at >+2000 m (+6562').
3
Maximum relative humidity when the unit temperature slowly increases, or when the unit temperature
directly increases from –25°C to +30°C (–13°F to +86°F)
4
Maximum absolute humidity when the unit temperature directly decreases from +70°C to +15°C
(+158°F to +59°F)

TYPE DESIGNATION

The type designations of the Thyro-PX DC power controllers are derived from the
construction of the unit power section, as shown in the following table.
Table 3‑9. Type designation
Type Range
Thyro-
PX DC
power
controller
57010241-00B
Temperature
–25°C to +70°C
–13°F to +158°F
Designation
3PX
..500
..690
.. ...-1800
.. ...-.... . H
.. ...-.... . . F
Specifications
Thyro‑PX
Relative Humidity
[3]
95%
3 [4]
60 g/m
Features
3-phase power section, for 3-phase operation
Up to 500 V
Up to 690 V
Type current 1800 A DC output current
Integrated semiconductor fuse
Forced air cooling with integrated fan
®
DC Power Controller
Air Pressure
65.6 kPa to 106 kPa
656 mbar to
1060 mbar
Equivalent altitude:
+3500 m to –500 m
(+11480' to –1640')
3‑6