Optical connectors
Diagnostics interface
Serial interface
Electrical data
Power supply
1)
Current consumption
Effective power loss
Overvoltage category
Fusing
Signaling contact
1)
Permitted ambient conditions
Ambient temperature
Relative humidity
Housing, dimensions and weight
Design
Housing material
SCALANCE XC-200
Operating Instructions, 12/2017, C79000-G8976-C442-03
7.2 Technical specifications SCALANCE XC206-2 (SC)
Quantity
Connector
Properties
Transmission speed
Cable type
Transmitter output (optical)
● Minimum
● Maximum
Receiver input
● Sensitivity min.
● Input power max.
Cable cross-section
Cable length
● 50/125 μm
● 0 ... 5 km
● 62.5/125 μm
● 0 ... 5 km
Quantity
Connector
Rated voltage
Voltage range (incl. tolerance)
Design
Properties
12 VDC
24 VDC
Quantity
Design
Permitted voltage range
Load capability
During operation up to 2000 m
During storage
During transportation
During operation at 25 ℃
compact
Basic housing
Front cover
Technical specifications
2
SC socket
Full duplex acc. to 100Base-FX
100 Mbps
Multimode glass FO cable
● -19 dBm
● -14 dBm
● -32 dBm
● -3 dBm
Attenuation
● ≤ 1 dB/km at 1310 nm; 1200 MHz * km
● ≤ 1 dB/km at 1310 nm; 1200 MHz * km
1
RJ-11 jack
12 to 24 VDC
9.6 to 31.2 VDC Safe Extra Low Voltage
(SELV)
Terminal block, 4 terminals
Implemented redundantly
500 mA
250 mA
6 W
CAT II
2.5 A / 125 V
1
Terminal block, 2 terminals
24 VDC
max. 100 mA
-40 °C to +70 °C
-40 ℃ to +85 ℃
-40 ℃ to +85 ℃
≤ 95 % no condensation
Die cast aluminum, powder coated
Polycarbonate (PC-GF10)