Siemens SIMATIC NET SCALANCE XC-200 Series Operating Instructions Manual page 50

Industrial ethernet switches
Table of Contents

Advertisement

Connecting up
5.1 Safety when connecting up
Safety notices when using the device according to Hazardous Locations (HazLoc)
If you use the device under HazLoc conditions you must also keep to the following safety
notices in addition to the general safety notices for protection against explosion:
EXPLOSION HAZARD
You may only connect or disconnect cables carrying electricity when the power supply is
switched off or when the device is in an area without inflammable gas concentrations.
Safety notices for use according to ATEX and IECEx
If you use the device under ATEX or IECEx conditions you must also keep to the following
safety notices in addition to the general safety notices for protection against explosion:
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).
Safety notice for connecting with a LAN ID (Local Area Network)
A LAN or LAN segment with all the interconnected devices should be contained completely
in a single low voltage power distribution in a building. The LAN is designed either for
"Environment A" according to IEEE802.3 or "Environment 0" according to IEC TR 62102.
Do not connect any electrical connectors directly to the telephone network (telephone network
voltage) or a WAN (Wide Area Network).
EXPLOSION HAZARD
Do not press the SELECT/SET button when there is an explosive atmosphere.
50
WARNING
WARNING
WARNING
WARNING
Operating Instructions, 12/2017, C79000-G8976-C442-03
SCALANCE XC-200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents