Siemens SIMATIC NET SCALANCE XC-200 Series Operating Instructions Manual page 15

Industrial ethernet switches
Table of Contents

Advertisement

● Factory setting
– Open
– Closed
● Authentication
Specifies whether or not the protocol is authenticated.
● Encryption
Specifies whether or not the transfer is encrypted.
Protocol
Port
TELNET
TCP/23
SSH
TCP/22
HTTP
TCP/80
HTTPS
TCP/443
SNMP
UDP/161
PROFINET
UDP/34964,
UDP/49154 -
UDP/49157
EtherNet/IP
TCP/44818,
UDP/2222,
UDP/44818
DHCP
UDP/67,
UDP/68
SCALANCE XC-200
Operating Instructions, 12/2017, C79000-G8976-C442-03
The factory setting of the port is "Open".
The factory setting of the port is "Closed".
Port status
Factory setting
Open (when config‐
Open
ured)
Open (when config‐
Open
ured)
Open (when config‐
Open
ured)
Open
Open
Open (when config‐
Open
ured)
Open
Open
Open (when config‐
Closed
ured)
(Open with Ethernet/
IP variants)
Open (when config‐
Closed
ured)
2.1 Recommendations on network security
Authentication
Encryption
Yes
No
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes (when configured)
No
No
No
No
No
No
Safety notices
15