Technical Specifications Scalance Xc206-2Sfp - Siemens SIMATIC NET SCALANCE XC-200 Series Operating Instructions Manual

Industrial ethernet switches
Table of Contents

Advertisement

Technical specifications

7.3 Technical specifications SCALANCE XC206-2SFP

Technical specifications
Degree of protection
Dimensions (W x H x D)
Weight
Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
Note the wiring rules (Page 51).
1)
7.3
Technical specifications SCALANCE XC206-2SFP
The following technical specifications apply to the SCALANCE XC206-2SFP.
Technical specifications
Attachment to Industrial Ethernet
Electrical connectors
Slots for pluggable transceivers
Diagnostics interface
Serial interface
Electrical data
Power supply
1)
Current consumption
Effective power loss
Overvoltage category
Fusing
62
IP20
60 x 145 x 125 mm
540 g
● Wall mounting
● Installation on a DIN rail
● Mounting on an S7-300 standard rail
● Mounting on an S7-1500 standard rail
> 46 years
Quantity
Connector
Properties
Transmission speed
Quantity
Connector
Transmission speed
Quantity
Connector
Rated voltage
Voltage range (incl. tolerance)
Design
Properties
12 VDC
Without SFP
With SFP
2)
24 VDC
Without SFP
With SFP
2)
Without SFP
With SFP
2)
6
RJ-45 jack
Half/full duplex, MDI‑X pinning
10 / 100 Mbps
2
SFP transceivers (LC port)
100 / 1000 Mbps
1
RJ-11 jack
12 to 24 VDC
9.6 to 31.2 VDC Safe Extra Low Voltage
(SELV)
Terminal block, 4 terminals
Implemented redundantly
400 mA
500 mA
200 mA
250 mA
4.8 W
6 W
CAT II
2.5 A / 125 V
Operating Instructions, 12/2017, C79000-G8976-C442-03