Intelligent Fast-Charging System
Fault or
Warning
Fault or Warning Message
Code
137
BMID BAT Over-Temp
138
BMID Comm Fail Port A
139
BMID Config Warning on Port A
BMID Temp Sensor Failure on Port A The BMID temperature sensor is out of
142
143
Vbat Mismatch on Port A
144
Battery Over-discharged on Port A
145
Early Charge Termination on Port A
164
Invalid Pilot on Port B
165
Chrg VDC Port B Low
166
Chrg VDC Port B High
167
BMID B Vbat Too Low
168
BMID VDC Too High
169
BMID BAT Over-Temp
31504-03-0101
GSE O&M for DVS300 / 330 / 330 IP55 / 400 and MVS330/400
Description
The battery temperature is too high.
The BMID link was lost after the
charge started.
The BMID is not adequately configured for
charger (power station) usage.
valid range.
The BMID and terminal voltages do not
match.
The battery is excessively discharged.
The charge unexpectedly terminated.
The battery was connected with an invalid
pilot circuit.
The battery voltage is too low for the charger
(power station).
The battery voltage is too high for the charger
(power station).
The battery voltage is too low for the BMID.
The battery voltage is too high for the BMID.
The battery temperature is too high.
38