Intelligent Fast-Charging System
6. Set the main/support configuration as follows:
A)
Power ON the system and wait for it to complete initialization tests. The display shows the
startup windows (Figure 6).
B)
Enter the key code down-arrow+Enter on the front panel (Figure 3) to display the Charger
Configuration Menu.
C)
Use the SELECT button to scroll to the Network Config. Setup menu, and press the ENTER
button. The next sub-menu allows the user to select the type of power server to be used with
the system.
D)
Select from the following options: COMM VARIABLE POWER, FIXED POWER 80 KW, FIXED
POWER 60 KW, FIXED POWER 40 KW, and FIXED POWER 33 KW.
Earlier versions of the power server use the COMM VARIABLE POWER mode. The NGPS
power server uses the FIXED POWER modes.
E)
Enter the number of ports to be configured in the system, once the desired power server mode
is configured. The number of ports in a system is twice the number of power stations, since
each power station in the system has two ports (A and B). The main power station is included
in the total port count. A system with 5 power stations (1 main and 4 support), therefore, would
be configured for 10 ports.
F)
Reboot the entire system by cycling the system power once the main station has been properly
configured (see section 4.2 System Startup). This step is necessary to complete the system
configuration.
Refer to the Intelligent Fast-Charging System Ground Support Equipment Installation Guide
PN 31504-76 for complete descriptions of the main/support station configuration