Intelligent Fast-Charging System
Fault or
Warning
Fault or Warning Message
Code
116
PS2 General Failure
117
PS2 Overtemp Failure
118
DCBus VDC Too Low
119
DCBus VDC Too High
120
Nt Flt-lost Port X/Lost Main
121
Network Cfg Failure
126
Temp Sensor Failure
129
Power Imbalance
132
Invalid Pilot on Port A
133
Chrg VDC Port A Low
134
Chrg VDC Port A High
135
BMID A Vbat Too Low
136
BMID VDC Too High
31504-03-0101
GSE O&M for DVS300 / 330 / 330 IP55 / 400 and MVS330/400
Description
Power stage #2 (port B) has a current
sensor fault.
Power stage #2 (port B) temperature is
too high.
The common DC bus voltage is too low.
The common DC bus voltage is too high.
Network Fault
Lost Port X / Lost Main
The Charger has invalid network Configura-
tion.
The temperature sensor reading is invalid.
There is a power stage power imbalance in
500-A mode.
The battery is connected with an invalid
pilot circuit.
The battery voltage is too low for the charger
(power station).
The battery voltage is too high for the charger
(power station).
The battery voltage is too low for the BMID.
The battery voltage is too high for the BMID.