Mounting; Mounting Requirements - Endress+Hauser Liquiphant FTL33 Operating Instructions Manual

Point level switch for liquids in the food industry
Hide thumbs Also See for Liquiphant FTL33:
Table of Contents

Advertisement

Liquiphant FTL33
5

Mounting

5.1

Mounting requirements

5.1.1
Orientation
Installation is possible in any position in a vessel, pipe or tank.
 2
Installation examples
1
Overfill prevention or upper level detection (maximum safety)
2
Dry running protection for pump (minimum safety)
3
Lower level detection (minimum safety)
5.1.2
Switch point
The switch point A on the sensor depends on the orientation of the point level switch (water
+25 °C (+77 °F), 1 bar (14.5 psi).
A
 3
Orientation: vertical from above, vertical from below, horizontal; dimensions in mm (in)
5.1.3
Viscosity
Switching delays may occur in the case of highly viscous liquids. Make sure that the liquid can
easily run off the tuning fork:
Endress+Hauser
3
A
1
2
A
Mounting
A0036961
A0020734
11

Advertisement

Table of Contents
loading

Table of Contents