Endress+Hauser Liquiphant FTL33 Operating Instructions Manual page 28

Point level switch for liquids in the food industry
Hide thumbs Also See for Liquiphant FTL33:
Table of Contents

Advertisement

Electrical connection
2-wire AC/DC
Terminal assignment
1
0.5A
L1/L+
Symbols
Description
Yellow LED (ye) lit
Yellow LED (ye) not lit
K
External load
Connection with cable
Depending on the assignment of the connector or the wiring of the cable, the device works in
either the MAX or MIN operating mode.
When the cable is wired, one wire of the cable does not have any function in each of the
operating modes (brown in the case of MIN, and gray in the case of MAX). The cable with no
function must be secured against inadvertent contact.
 15
Cable (cannot be disassembled)
28
2
>20 V
K
N/L–
A0021220
MIN operating mode
1
2
1
2
Liquiphant FTL33
Yellow LED (ye)
A0045070
A0045069
A0022902
Endress+Hauser

Advertisement

Table of Contents
loading

Table of Contents